无法使用GTID

通过配置文件没办法开启gtid,重启mysql后也没用.可以进入mysql设置临时的,但是服务一重启就又变成gtid_model=off.
Mysql版本5.7和8.0都试过不行.
配置

gtid_mode = on
enforce_gtid_consistency = on
master_info_repository = TABLE
relay_log_info_repository = TABLE

MySQL [(none)]> show variables like '%gtid%';
+----------------------------------+-----------+
| Variable_name                    | Value     |
+----------------------------------+-----------+
| binlog_gtid_simple_recovery      | ON        |
| enforce_gtid_consistency         | OFF       |
| gtid_executed_compression_period | 1000      |
| gtid_mode                        | OFF       |
| gtid_next                        | AUTOMATIC |
| gtid_owned                       |           |
| gtid_purged                      |           |
| session_track_gtids              | OFF       |
+----------------------------------+-----------+
8 rows in set (0.01 sec)

完整配置

[client]
port = 3306
socket = /tmp/mysql.sock

[mysql]
prompt="MySQL [\d]> "
no-auto-rehash

[mysqld]
port = 3306
socket = /tmp/mysql.sock

basedir = /usr/local/mysql
datadir = /data/mysql
pid-file = /data/mysql/mysql.pid
user = mysql
bind-address = 0.0.0.0
server-id = 1

init-connect = 'SET NAMES utf8mb4'
character-set-server = utf8mb4

skip-name-resolve
back_log = 300

max_connections = 324
max_connect_errors = 6000
open_files_limit = 65535
table_open_cache = 128
max_allowed_packet = 500M
binlog_cache_size = 1M
max_heap_table_size = 8M
tmp_table_size = 16M

read_buffer_size = 2M
read_rnd_buffer_size = 8M
sort_buffer_size = 8M
join_buffer_size = 8M
key_buffer_size = 4M

thread_cache_size = 8

query_cache_type = 1
query_cache_size = 8M
query_cache_limit = 2M

ft_min_word_len = 4

log_bin = /data/mysql/mysql-bin
binlog_format = ROW
expire_logs_days = 7

log_error = /data/mysql/mysql-error.log
slow_query_log = 1
long_query_time = 1
slow_query_log_file = /data/mysql/mysql-slow.log

performance_schema = 0
explicit_defaults_for_timestamp



skip-external-locking

default_storage_engine = InnoDB
innodb_file_per_table = 1
innodb_open_files = 500
innodb_buffer_pool_size = 64M
innodb_write_io_threads = 4
innodb_read_io_threads = 4
innodb_thread_concurrency = 0
innodb_purge_threads = 1
innodb_flush_log_at_trx_commit = 2
innodb_log_buffer_size = 2M
innodb_log_file_size = 32M
innodb_log_files_in_group = 3
innodb_max_dirty_pages_pct = 90
innodb_lock_wait_timeout = 120

bulk_insert_buffer_size = 8M
myisam_sort_buffer_size = 8M
myisam_max_sort_file_size = 10G
myisam_repair_threads = 1

interactive_timeout = 28800
wait_timeout = 28800

[mysqldump]
quick
max_allowed_packet = 500M

[myisamchk]
key_buffer_size = 8M
sort_buffer_size = 8M
read_buffer = 4M
write_buffer = 4M

gtid_mode = on
enforce_gtid_consistency = on
master_info_repository = TABLE
relay_log_info_repository = TABLE

正在回答

1回答

你的系统中可能存在着多个my.cnf文件,MySQL在启动时会按顺序应用my.cnf文件的配置,并且后面应用的会覆盖前面的配置。你可以使用find / -name my.cnf查找一下看看。

0 回复 有任何疑惑可以回复我~
  • 提问者 已经快秃顶了呢 #1
    系统就一个my.cnf的.
    回复 有任何疑惑可以回复我~ 2020-01-05 18:53:34
  • sqlercn 回复 提问者 已经快秃顶了呢 #2
    在MySQL8.0中用set persist gtid_mode=on 试一下。
    回复 有任何疑惑可以回复我~ 2020-01-05 21:04:13
  • 提问者 已经快秃顶了呢 回复 sqlercn #3
    还是不行,是不是我虚拟机装的mysql,又问题?8.0安装:wget -c http://mirrors.linuxeye.com/oneinstack-full.tar.gz && tar xzf oneinstack-full.tar.gz && ./oneinstack/install.sh --db_option 1 --dbinstallmethod 1 --dbrootpwd qvbilam   5.7安装:wget -c http://mirrors.linuxeye.com/oneinstack-full.tar.gz && tar xzf oneinstack-full.tar.gz && ./oneinstack/install.sh --db_option 2 --dbinstallmethod 1 --dbrootpwd qvbilam   文档:https://oneinstack.com/docs/lnmptstack-image-guide/
    回复 有任何疑惑可以回复我~ 2020-01-06 00:36:42
问题已解决,确定采纳
还有疑问,暂不采纳